When you test the thermistor, just connect one side to the circuit board, the other side do not connect to the extruder:
If the LCD display shows indoors temperature, the thermistor is good, the port on the circuit board is broken;
If the LCD display shows not indoors temperature, but negative, the thermistor is broken.